Commercial glass in Michigan is regulated at two levels: safety glazing rules that decide where glass must resist human impact, and energy rules that decide how storefront glass must perform thermally. Both apply to most storefront and entrance projects, and both are enforced through the local building department.
Here's what the 2015 Michigan Building Code actually requires for commercial storefront and entrance glass, which products qualify as safety glazing, and where the common compliance traps sit. Two cautions up front: adopted code editions change, and local jurisdictions can add amendments, so project-specific answers belong with your local building department. In code language, that's the authority having jurisdiction (AHJ).
Four documents do most of the work on a Michigan commercial glazing project.
| Code or standard | What it governs | Who enforces or certifies |
| 2015 Michigan Building Code, Chapter 24 (adopts IBC 2015 with Michigan amendments) | Where safety glazing is required, glass loads, guards, structural glazing | Local building department (AHJ) |
| CPSC 16 CFR 1201 | Federal consumer safety standard for glazing in doors and other architectural products | Manufacturers; verified through certification labels |
| ANSI Z97.1 | Voluntary safety performance standard for glazing materials | Third-party certification bodies such as SGCC |
| 2021 Michigan Commercial Energy Code | Maximum U-factor and solar heat gain for storefront fenestration | Local building department (AHJ) |
The practical split: Chapter 24 of the building code answers "where must this glass be safety glazing," CPSC and ANSI answer "does this product qualify," and the energy code answers "how must this glass perform against Michigan weather."
Safety glazing is not one product. It's any glazing that passes impact testing and breaks in a way that reduces injury. Two product families dominate commercial work.
Tempered glass is heat-treated to roughly four times the strength of ordinary annealed glass. When it breaks, it crumbles into small, blunt granules instead of long sharp shards. That's why it's the default for entrance doors, sidelites, and most hazardous locations.
Laminated glass bonds two lites of glass to a tough plastic interlayer. When it breaks, fragments stay attached to the interlayer and the panel largely remains in its frame. That makes laminated glass the pick where fallout or security matters, such as overhead glazing, guards, and some security applications.
Under CPSC 16 CFR 1201, compliant glazing falls into two impact classes. Category I covers smaller lites and Category II covers larger panels, with Category II tested to a higher impact level. ANSI Z97.1 provides a parallel voluntary standard used for certifying glass and plastic glazing materials. The proof is on the glass itself: each lite of safety glazing carries a permanent etched or sandblasted label identifying the manufacturer and the standard it meets, and a valid SGCC certification listing confirms the product behind that label.
Section 2406 of the building code defines "hazardous locations": the spots where human impact is likely enough that ordinary annealed glass is off the table. For storefronts and entrances, four situations cover nearly every project.
Glazing in the fixed and operable panels of swinging, sliding, and bifold doors is a hazardous location under Section 2406.4.1. A full-lite glass entrance door is therefore always safety glazing, with narrow exceptions for small decorative panels and protective barriers on the push side.
Panels beside a door are hazardous when the glass sits within 24 inches of either vertical edge of the closed door and the bottom edge is less than 60 inches above the walking surface. This rule pulls most entrance sidelites into safety glazing. It's also the one most often missed on storefront retrofits.
Individual glass panels are hazardous when all of the following are true: the pane is larger than 9 square feet, the bottom edge is less than 18 inches above the floor, the top edge is more than 36 inches above the walking surface, and a walking surface sits within 36 inches horizontally of the glass. Floor-to-ceiling storefront lites almost always trip this test, which is why modern storefronts are tempered or laminated as a matter of course.
Glass used in guards and railings is regulated under Section 2406.4.4 and Section 2407, which require laminated or otherwise restrained glazing in most guard applications. Glazing in wet areas, near stairways and ramps, and at the bottom of stairway landings is also hazardous under Sections 2406.4.5 through 2406.4.7. Interior vestibules, display windows, and partition glass can fall under these rules too, depending on where people walk. The safety-glass and hardware logic behind glass guards is covered in more depth in our breakdown of whether glass railings are safe and what code requires.
A full-lite glass entrance door is always safety glazing, no exceptions to plan around at order time. Sidelites and transom glass framing that door fall under the 24-inch adjacency rule, so assume they are safety glazing unless a measurement says otherwise.
Floor-to-ceiling storefront panels are caught by the 9-square-foot window rule in nearly every real layout. Interior vestibule walls and glass office partitions near doors are evaluated the same way as exterior glass. And glass guards along mezzanines, stairs, or raised interior floors need laminated glazing or an engineered top rail, a requirement that changed guard design across the industry.
At order time, each of these answers translates directly into the spec: tempered for most vertical impact zones, laminated where retention or security matters, and certified product labels documented for the permit file.
Safety is only half the spec. Michigan's 2021 Commercial Energy Code caps U-factor and solar heat gain coefficient (SHGC) for storefront fenestration. In practice, that pushes new commercial work toward insulated glass units with low-emissivity coatings.
Two things follow. First, safety glazing and energy glazing are separate requirements that get answered in one product decision: a storefront lite usually has to be both tempered and part of an insulated unit. Second, Michigan's climate is heating-dominated, so the storefront's U-factor hits operating cost directly. Glass selection deserves attention beyond minimum compliance. For a deeper look at the efficiency side, see our guide to energy-efficient commercial glazing for Lansing businesses.
Replacement glass must meet the same safety-glazing requirements as new installations. Under Section 2401.2 of the code, when an existing lite in a hazardous location is replaced, the new glass must comply with the current safety-glazing rules.
For older Michigan storefronts, that has a real consequence: a cracked annealed panel in a hazardous location can't legally go back in as annealed glass. The replacement must be safety glazing. It's one reason a seemingly simple pane swap sometimes turns into a small upgrade project.
Most modern storefronts use tempered safety glass, typically as part of an insulated glass unit for energy performance. Laminated glass is used where security, sound control, or fragment retention matters. Single-pane storefronts are generally 1/4-inch glass, and building codes require safety glazing in doors, beside doors, and in large low panels.
Tempered or equivalent safety glazing is required in glass doors, in panels within 24 inches of a door's vertical edge and less than 60 inches above the floor, in individual panes over 9 square feet that extend near walking surfaces, in glass guards, in wet areas, and near stairs and ramps. The full list lives in Section 2406 of the building code.
Glass qualifies as safety glazing by passing impact testing under CPSC 16 CFR 1201 or ANSI Z97.1 and carrying a permanent certification label. Tempered glass, which crumbles into small blunt pieces, and laminated glass, which holds together on a plastic interlayer, are the two common compliant types.
Not all of it, but most glass in the impact zones of a storefront must be some form of safety glazing. Doors, sidelites near doors, and large low panels require it. Upper panels outside the hazardous-location definitions can legally be annealed glass, though many projects use tempered or laminated throughout for simplicity and durability.
Yes. Replacement glazing must comply with the safety-glazing requirements that apply to new work. If an existing pane sits in a hazardous location, its replacement must be certified safety glazing even if the original glass was not.
Code compliance is baked into how we spec commercial work. Every storefront and entrance project gets glass matched to the location's requirements: tempered for impact zones, laminated where retention matters, insulated low-E units where the energy code and Michigan winters call for them. We fabricate replacements in our own Mason shop, so the right glass shows up on a schedule the project can actually plan around.
Planning a storefront or entrance project in the Lansing area? Contact Spartan Glass & Mirror for an itemized quote that spells out the glass spec before any work begins.
Ready for expert glass solutions for your home or business? Spartan Glass & Mirror has been serving the Lansing-East Lansing metropolitan area
and surrounding areas for over 30 years. Fill out the form below or call for your free estimate!